POE-SW804G-SOLAR
4 Ports MPPT Solar PoE Switch
Quick Guide (V2.1/2026-9-2)
Package Contents
Solar Interface
Solar Installation
For safety, please follow the installation order shown above:
①Load (optional RS485) > ②Battery > ③Solar Panel
*If your battery type is not a 12V LiFePO₄ battery, please complete step ② and then refer to the instructions below under
"Battery Type Set Up
" before step ③ connecting the solar panel.
If you are using a battery other than a 12V LiFePO₄, configuration is required via a RS485 to USB cable (sold separately) and software on your PC. Please follow the steps below:
A. Download and install the Linovision PC configuration software
"LINOVISION Tool Box
" from the link provided.
B. Connect the RS485 to USB cable, Red wire to terminal A, Blue wire to terminal B. Plug the USB end into your PC, then connect the XT60 interface to the battery.
C. Run the
"LINOVISION Tool Box
"
. Select the corresponding port. Set the device model to Solar-CMP10A/POE-SW804G-SOLAR, then click "Start"
and "Config
" to enter the configuration interface.
*If you need to manually configure a 24V battery, please fill in each parameter as if for a 12V system and set the system voltage level to 24V — the system will automatically double the values during actual operation.
Battery Type Set Up Reference
- For gel and lead-acid batteries, the POE-SW804G-Solar controller comes with builtin charge curves and 12V/24V auto-detection so only battery type selection is needed.
- For LiFePO₄ and NMC batteries, configuration must be done according to the actual battery specifications. The 24V information is for reference only. When filling in the parameters, you should still enter values based on a 12V system and only change the system voltage level to 24V.
| 12V LiFePO4 (4S) | 24V LiFePO4 (8S) | 12V NMC (3S) | 24V NMC (7S) |
| Charging Voltage | 14.4V | 28.8V | 12.6V | 29.4V |
| Charging Current | 10.0A | 10.0A | 10.0A | 10.0A |
| Charging End Current | 0.5A | 0.5A | 0.5A | 0.5A |
| Over-Discharge Voltage | 11.2V | 22.4V | 9.0V | 21.0V |
| Over-Discharge Recovery Voltage | 12.3V | 23.6V | 9.9V | 22.2V |
| Over-Voltage Voltage | 15.0V | 30.0V | 13.0V | 30.8V |
| Float Charge Voltage | 14.2V | 28.4V | 12.3V | 28.7V |
| Boost Charge Voltage | 14.4V | 28.8V | 12.6V | 29.4V |
| High-Temperature Charge Protection | 55°C | 55°C | 50°C | 50°C |
| High-Temperature Discharge Protection | 60°C | 60°C | 60°C | 60°C |
| Low-Temperature Charge Protection | 0°C | 0°C | 0°C | 0°C |
| Low-Temperature Discharge Protection | -20°C | -20°C | -20°C | -20°C
|
Troubleshooting
| Symptom | Possible Cause | Corrective Action |
PV status indicator LED is off in daylight; load lamp switches on in daylight; load lamp operates for only one night | Photovoltaic module wiring incorrect | Verify and correct the photovoltaic module wiring |
Load status indicator LED flashes rapidly; load lamp does not illuminate | Load lamp wiring short-circuited or open-circuited; load lamp defective | Inspect and repair the load lamp wiring; replace the lamp if necessary |
Load status indicator LED flashes rapidly; load lamp flickers | The load lamp turns off immediately after lighting, and the load status indicator LED flashes rapidly. | Adjust the consumption of load lamp to the range specified in the controller datasheet |
| Load status indicator LED flashes slowly | Load power exceeds the controller's rated capacity | Reduce the output current to within the controller's rating |
BAT status indicator LED is red; lighting duration is insufficient | Battery deeply discharged; excessive cable resistance; battery damaged | Confirm proper charging conditions and remove any shading of the photovoltaic module; shorten or tighten battery cables; replace the battery if required |
Cloud Connection