POE-SW804G-SOLAR - Quick Guide

POE-SW804G-SOLAR - Quick Guide

POE-SW804G-SOLAR

4 Ports MPPT Solar PoE Switch
Quick Guide (V2.1/2026-9-2)

Package Contents



Solar Interface



Solar Installation

For safety, please follow the installation order shown above:
①Load (optional RS485) > ②Battery > ③Solar Panel
*If your battery type is not a 12V LiFePO₄ battery, please complete step ② and then refer to the instructions below under "Battery Type Set Up " before step ③ connecting the solar panel.

Battery Type Set Up


If you are using a battery other than a 12V LiFePO₄, configuration is required via a RS485 to USB cable (sold separately) and software on your PC. Please follow the steps below:
A. Download and install the Linovision PC configuration software "LINOVISION Tool Box " from the link provided.
https://github.com/LINOVISION-CLOUD/Serial-port-application/releases




B. Connect the RS485 to USB cable, Red wire to terminal A, Blue wire to terminal B. Plug the USB end into your PC, then connect the XT60 interface to the battery.

C. Run the "LINOVISION Tool Box " . Select the corresponding port. Set the device model to Solar-CMP10A/POE-SW804G-SOLAR, then click "Start" and "Config " to enter the configuration interface.
*If you need to manually configure a 24V battery, please fill in each parameter as if for a 12V system and set the system voltage level to 24V — the system will automatically double the values during actual operation.



Battery Type Set Up Reference

  1. For gel and lead-acid batteries, the POE-SW804G-Solar controller comes with builtin charge curves and 12V/24V auto-detection so only battery type selection is needed.
  1. For LiFePO₄ and NMC batteries, configuration must be done according to the actual battery specifications. The 24V information is for reference only. When filling in the parameters, you should still enter values based on a 12V system and only change the system voltage level to 24V.
12V LiFePO4 (4S)24V LiFePO4 (8S)12V NMC (3S)24V NMC (7S)
Charging Voltage14.4V28.8V12.6V29.4V
Charging Current10.0A10.0A10.0A10.0A
Charging End Current0.5A0.5A0.5A0.5A
Over-Discharge Voltage11.2V22.4V9.0V21.0V
Over-Discharge Recovery Voltage12.3V23.6V9.9V22.2V
Over-Voltage Voltage15.0V30.0V13.0V30.8V
Float Charge Voltage14.2V28.4V12.3V28.7V
Boost Charge Voltage14.4V28.8V12.6V29.4V
High-Temperature Charge Protection55°C55°C50°C50°C
High-Temperature Discharge Protection60°C60°C60°C60°C
Low-Temperature Charge Protection0°C0°C0°C0°C
Low-Temperature Discharge Protection-20°C-20°C-20°C-20°C


Troubleshooting

SymptomPossible CauseCorrective Action
PV status indicator LED is off in daylight;
load lamp switches on in daylight;
load lamp operates for only one night
Photovoltaic module wiring incorrectVerify and correct the photovoltaic module wiring
Load status indicator LED flashes rapidly;
load lamp does not illuminate
Load lamp wiring short-circuited or open-circuited;
load lamp defective
Inspect and repair the load lamp wiring;
replace the lamp if necessary
Load status indicator LED flashes rapidly;
load lamp flickers
The load lamp turns off immediately after lighting, and the load status indicator LED flashes rapidly.Adjust the consumption of load lamp to the range specified in the controller datasheet
Load status indicator LED flashes slowlyLoad power exceeds the controller's rated capacityReduce the output current to within the controller's rating
BAT status indicator LED is red;
lighting duration is insufficient
Battery deeply discharged;
excessive cable resistance;
battery damaged
Confirm proper charging conditions and remove any shading of the photovoltaic module;
shorten or tighten battery cables;
replace the battery if required


Cloud Connection